{"id":1324,"date":"2026-08-25T10:34:10","date_gmt":"2026-08-25T10:34:10","guid":{"rendered":"https:\/\/masind.net\/blog\/?p=1324"},"modified":"2026-08-25T11:29:09","modified_gmt":"2026-08-25T11:29:09","slug":"fuji-drive-fault-codes-elevator","status":"publish","type":"post","link":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/","title":{"rendered":"What Is the Complete Fuji Drive Fault Codes List for Elevator Systems?"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">Elevator systems lean on Variable Voltage Variable Frequency (VVVF) drives to get smooth acceleration, tight speed control, and reliable operation out of the motor. Fuji drives show up a lot in elevators for exactly this reason, they perform well, run efficiently, and come loaded with protection features. Like any smart drive system, they&#8217;re constantly watching operating conditions in the background, and the moment something looks off, a fault code shows up on the display.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Getting familiar with Fuji drive fault codes helps technicians spot problems fast, cut down on downtime, and avoid the kind of failures that get expensive quickly. Whether it&#8217;s the power supply, the motor, encoder feedback, communication, or overheating causing the trouble, the fault code on screen is really just the starting point of the investigation.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Before diving into troubleshooting any code, it helps to understand how the drive actually controls elevator movement in the first place. Our guide on <\/span><a href=\"https:\/\/masind.net\/blog\/how-drives-work-in-an-elevator\/\"><b>How Drives Work in an Elevator<\/b><\/a><span style=\"font-weight: 400;\"> covers the role VVVF drives, motors, controllers, and braking systems play in keeping the ride smooth and efficient.<\/span><\/p>\n<h2><b>What Are Fuji Drive Fault Codes?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Fuji drive fault codes are diagnostic messages the elevator drive throws up the moment it picks up on an operating condition that&#8217;s outside normal limits. They exist to protect the drive, the motor, and the elevator system from damage, while also giving maintenance teams a head start on finding the actual source of the problem.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Depending on which drive model you&#8217;re dealing with, a fault code might point to an electrical issue, a mechanical one, a communication breakdown, a temperature warning, or something as simple as a parameter that&#8217;s set up wrong.<\/span><\/p>\n<h2><b>Common Categories of Fuji Drive Fault Codes<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Specific codes vary between Fuji drive models, but most of them fall into a handful of general categories.<\/span><\/p>\n<h3><b>Power Supply Faults<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Power-related faults tend to show up when the incoming voltage is unstable or drifts outside the recommended range.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Common issues include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Overvoltage<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Undervoltage<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Input phase loss<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">DC bus voltage abnormalities<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Power interruption<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">These can trace back to unstable electrical supply, damaged wiring, or a faulty power distribution component.<\/span><\/p>\n<h3><b>Motor Protection Faults<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The drive keeps a constant eye on motor performance so it can step in before excess current or abnormal conditions do any real damage.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Typical motor-related faults include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Motor overload<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Overcurrent<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Ground fault<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Motor overheating<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Motor stall detection<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Brush off repeated motor faults for too long, and you&#8217;re looking at shorter equipment life and repair bills that add up fast.<\/span><\/p>\n<h3><b>Encoder Faults<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Most modern elevator systems rely on encoders for accurate speed and position feedback.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Common encoder-related problems include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Encoder signal loss<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Feedback error<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Pulse detection failure<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Speed feedback interruption<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Loose wiring, damaged encoder cables, and faulty encoder units are the usual suspects behind these.<\/span><\/p>\n<h3><b>Communication Faults<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Elevator drives are constantly talking to controllers, monitoring systems, and other electronic components.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Communication faults can include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Serial communication failure<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Controller communication timeout<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Parameter transmission error<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Network interruption<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">These usually come down to damaged communication cables or a configuration setting that&#8217;s off. Communication-related fault codes can also trace back to the elevator control system itself. Our guide on <\/span><a href=\"https:\/\/masind.net\/blog\/elevator-controller\/\"><b>What Is an Elevator Controller<\/b><\/a><span style=\"font-weight: 400;\">? A Beginner&#8217;s Guide to the Elevator&#8217;s Brain goes into how controllers talk to drives, motors, sensors, and safety devices, worth a read if that&#8217;s where the trail leads.<\/span><\/p>\n<h3><b>Temperature Protection Faults<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Fuji drives come with built-in temperature sensors specifically to protect the internal electronics.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Temperature-related alarms tend to come from:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Drive overheating<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Cooling fan failure<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High heat sink temperature<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Poor ventilation<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Keeping things clean and making sure airflow isn&#8217;t blocked goes a long way toward keeping overheating faults off your list.<\/span><\/p>\n<h2><b>Most Common Fuji Drive Faults and Their Causes<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Some faults show up during maintenance a lot more often than others.<\/span><\/p>\n<h3><b>Overvoltage Fault<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">An overvoltage fault usually pops up when the DC bus voltage climbs past the safe operating limit. Sudden regenerative energy during braking, or just unstable incoming power, can both trigger it.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Worth checking: the power supply, the braking resistors, and the regenerative braking components.<\/span><\/p>\n<h3><b>Undervoltage Fault<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Drop the input voltage too low and the drive simply can&#8217;t do its job properly.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A few usual suspects:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Weak power supply<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Loose electrical connections<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Power outages<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Faulty circuit breakers<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Don&#8217;t just restart the elevator and hope. Check the incoming voltage first.<\/span><\/p>\n<h3><b>Overcurrent Fault<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">This one&#8217;s straightforward, too much current is running through the motor or the drive.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">What tends to cause it:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Short circuits<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Mechanical overload<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Seized motor bearings<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Incorrect acceleration settings<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">This isn&#8217;t one to sit on. Get it inspected right away, because waiting around risks damage that won&#8217;t be cheap to fix.<\/span><\/p>\n<h3><b>Encoder Error<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Feedback from the encoder is what keeps elevator movement stable. Lose that, and things can get shaky or grind to a stop entirely.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Worth inspecting:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Encoder cable connections<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Encoder alignment<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Connector damage<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Feedback wiring<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Swapping out the damaged encoder component is often all it takes to fix this.<\/span><\/p>\n<h3><b>Drive Overheating<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Too much heat shortens the life of the electronics and can force an automatic shutdown.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Common reasons include:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Blocked ventilation<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Dirty cooling fans<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">High ambient temperature<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Continuous heavy operation<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Routine maintenance is really the best defense here.<\/span><\/p>\n<h2><b>How to Troubleshoot Fuji Drive Fault Codes<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">When a fault code shows up, work through it methodically rather than jumping straight to replacing parts.<\/span><\/p>\n<p><b>Step 1: Record the Fault Code<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Prior to handling any components, take notes on everything currently displayed on the screen. The drive can be easily reset, resulting in the loss of the information on the screen.<\/span><\/p>\n<p><b>Step 2: Check the Power Supply<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Take a meter and verify the input voltage level. By the way, have a look at the electrical connections to see if anything is loose or damaged.<\/span><\/p>\n<p><b>Step 3: Inspect the Motor<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Listen. Unusual noise, signs of overheating, mechanical resistance when it shouldn&#8217;t be there, or insulation that&#8217;s starting to break down, all worth ruling out here.<\/span><\/p>\n<p><b>Step 4: Verify Encoder Connections<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Check that the encoder cables are seated properly and haven&#8217;t picked up any physical damage along the way.<\/span><\/p>\n<p><b>Step 5: Review Drive Parameters<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Sometimes the fault isn&#8217;t hardware at all, it&#8217;s a parameter set wrong that&#8217;s tripping the protection function. Pull up the manufacturer&#8217;s recommended configuration and compare it against what&#8217;s currently set.<\/span><\/p>\n<p><b>Step 6: Reset the Drive<\/b><\/p>\n<p><span style=\"font-weight: 400;\">Fixed the issue? Reset the drive using the manufacturer&#8217;s procedure, then watch how the elevator runs for a bit afterward, don&#8217;t just walk away assuming it&#8217;s solved.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">If the same fault keeps coming back, that&#8217;s a sign to dig deeper before putting the elevator back into service.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">If the same fault keeps coming back, that&#8217;s a sign to dig deeper before putting the elevator back into service.<\/span><\/p>\n<h2><b>Preventive Maintenance Tips<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">A solid preventive maintenance routine cuts down on unexpected downtime and stretches the life of Fuji drives considerably.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Worth building into a routine:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Clean cooling fans and air filters regularly.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Inspect electrical terminals for loose connections.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check encoder cables during scheduled maintenance.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Monitor motor insulation resistance.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Verify brake operation periodically.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Keep firmware and parameters properly documented.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Record recurring fault history for trend analysis.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Staying consistent with maintenance is usually what catches a problem while it&#8217;s still small, long before it turns into a critical failure.<\/span><\/p>\n<h2><b>When Should You Contact a Professional?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Minor stuff, a loose wire here and there, can usually get sorted during routine maintenance. Recurring fault codes are a different story and shouldn&#8217;t get brushed aside.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Bring in a professional when:<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The same fault appears repeatedly.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The drive overheats frequently.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The elevator stops unexpectedly.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Communication faults persist after cable inspection.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Motor or brake faults continue after repairs.<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Trying to bypass safety protections isn&#8217;t worth the risk it creates, for passengers and maintenance staff alike.<\/span><\/p>\n<h2><b>Conclusion<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Fuji drive fault codes exist to catch electrical, mechanical, and communication problems before they turn into serious equipment damage. The exact codes vary from one Fuji drive model to the next, but understanding the major fault categories and sticking to a structured troubleshooting process makes diagnosing issues a lot faster and more reliable.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Staying on top of preventive maintenance, keeping parameters properly managed, and inspecting motors, encoders, power supplies, and cooling systems on schedule all add up to fewer surprise breakdowns and a more reliable elevator overall. For fault definitions and fixes specific to your model, always check the official service manual for the Fuji drive actually installed in the system.<\/span><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Elevator systems lean on Variable Voltage Variable Frequency (VVVF) drives to get smooth acceleration, tight speed control, and reliable operation out of the motor. Fuji drives show up a lot in elevators for exactly this&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1326,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Fuji Drive Fault Codes List for Elevator Systems<\/title>\n<meta name=\"description\" content=\"Check common Fuji drive fault codes for elevator systems, their meanings, possible causes and troubleshooting steps for lift drive faults and errors.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fuji Drive Fault Codes List for Elevator Systems\" \/>\n<meta property=\"og:description\" content=\"Check common Fuji drive fault codes for elevator systems, their meanings, possible causes and troubleshooting steps for lift drive faults and errors.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/\" \/>\n<meta property=\"og:site_name\" content=\"MAS blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-25T10:34:10+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-25T11:29:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/08\/Mas-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"750\" \/>\n\t<meta property=\"og:image:height\" content=\"350\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/\",\"url\":\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/\",\"name\":\"Fuji Drive Fault Codes List for Elevator Systems\",\"isPartOf\":{\"@id\":\"https:\/\/masind.net\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/08\/Mas-1.png\",\"datePublished\":\"2026-08-25T10:34:10+00:00\",\"dateModified\":\"2026-08-25T11:29:09+00:00\",\"author\":{\"@id\":\"https:\/\/masind.net\/blog\/#\/schema\/person\/17d631215febbdc029be2d12116fbcf2\"},\"description\":\"Check common Fuji drive fault codes for elevator systems, their meanings, possible causes and troubleshooting steps for lift drive faults and errors.\",\"breadcrumb\":{\"@id\":\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#primaryimage\",\"url\":\"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/08\/Mas-1.png\",\"contentUrl\":\"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/08\/Mas-1.png\",\"width\":750,\"height\":350},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/masind.net\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"What Is the Complete Fuji Drive Fault Codes List for Elevator Systems?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/masind.net\/blog\/#website\",\"url\":\"https:\/\/masind.net\/blog\/\",\"name\":\"MAS blog\",\"description\":\"Just another WordPress site\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/masind.net\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/masind.net\/blog\/#\/schema\/person\/17d631215febbdc029be2d12116fbcf2\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/masind.net\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/d7375bd2ffc3d4c2030fb3812811d26388a1486dbcb3414bf3123f1961507ba6?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/d7375bd2ffc3d4c2030fb3812811d26388a1486dbcb3414bf3123f1961507ba6?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"http:\/\/localhost:8888\/idigitaliseblog\"],\"url\":\"https:\/\/masind.net\/blog\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fuji Drive Fault Codes List for Elevator Systems","description":"Check common Fuji drive fault codes for elevator systems, their meanings, possible causes and troubleshooting steps for lift drive faults and errors.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/","og_locale":"en_US","og_type":"article","og_title":"Fuji Drive Fault Codes List for Elevator Systems","og_description":"Check common Fuji drive fault codes for elevator systems, their meanings, possible causes and troubleshooting steps for lift drive faults and errors.","og_url":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/","og_site_name":"MAS blog","article_published_time":"2026-08-25T10:34:10+00:00","article_modified_time":"2026-08-25T11:29:09+00:00","og_image":[{"width":750,"height":350,"url":"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/08\/Mas-1.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/","url":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/","name":"Fuji Drive Fault Codes List for Elevator Systems","isPartOf":{"@id":"https:\/\/masind.net\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#primaryimage"},"image":{"@id":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#primaryimage"},"thumbnailUrl":"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/08\/Mas-1.png","datePublished":"2026-08-25T10:34:10+00:00","dateModified":"2026-08-25T11:29:09+00:00","author":{"@id":"https:\/\/masind.net\/blog\/#\/schema\/person\/17d631215febbdc029be2d12116fbcf2"},"description":"Check common Fuji drive fault codes for elevator systems, their meanings, possible causes and troubleshooting steps for lift drive faults and errors.","breadcrumb":{"@id":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#primaryimage","url":"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/08\/Mas-1.png","contentUrl":"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/08\/Mas-1.png","width":750,"height":350},{"@type":"BreadcrumbList","@id":"https:\/\/masind.net\/blog\/fuji-drive-fault-codes-elevator\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/masind.net\/blog\/"},{"@type":"ListItem","position":2,"name":"What Is the Complete Fuji Drive Fault Codes List for Elevator Systems?"}]},{"@type":"WebSite","@id":"https:\/\/masind.net\/blog\/#website","url":"https:\/\/masind.net\/blog\/","name":"MAS blog","description":"Just another WordPress site","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/masind.net\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/masind.net\/blog\/#\/schema\/person\/17d631215febbdc029be2d12116fbcf2","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/masind.net\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d7375bd2ffc3d4c2030fb3812811d26388a1486dbcb3414bf3123f1961507ba6?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7375bd2ffc3d4c2030fb3812811d26388a1486dbcb3414bf3123f1961507ba6?s=96&d=mm&r=g","caption":"admin"},"sameAs":["http:\/\/localhost:8888\/idigitaliseblog"],"url":"https:\/\/masind.net\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/posts\/1324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/comments?post=1324"}],"version-history":[{"count":1,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/posts\/1324\/revisions"}],"predecessor-version":[{"id":1325,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/posts\/1324\/revisions\/1325"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/media\/1326"}],"wp:attachment":[{"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/media?parent=1324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/categories?post=1324"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/tags?post=1324"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}