{"id":1342,"date":"2026-10-28T14:08:48","date_gmt":"2026-10-28T14:08:48","guid":{"rendered":"https:\/\/masind.net\/blog\/?p=1342"},"modified":"2026-11-10T13:01:18","modified_gmt":"2026-11-10T13:01:18","slug":"elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits","status":"publish","type":"post","link":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/","title":{"rendered":"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits"},"content":{"rendered":"<p><span style=\"font-weight: 400;\">When a power failure suddenly occurs, it can interrupt the operation of the elevator and can leave the passengers stuck and waiting inside the cabin. In such situations, an appropriately configured Automatic Rescue Device (ARD) can help move the elevator to a suitable landing so passengers can exit safely, provided the system is designed for that function and its operating conditions are met.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">An <\/span><b>Elevator Automatic Rescue Device<\/b><span style=\"font-weight: 400;\"> is an important part of emergency planning for compatible lift systems. It uses a backup power source and control arrangements to carry out a defined rescue sequence when the normal power supply fails.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For building owners, lift buyers, facility managers, and technicians, understanding how an ARD works is essential when evaluating elevator safety features. This guide explains its working principle, main components, benefits, maintenance requirements, and selection considerations.<\/span><\/p>\n<h2><b>What Is an Elevator Automatic Rescue Device?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An Automatic Rescue Device (ARD) is a system used to aid in elevator rescue operations when there is a power outage.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The ARD detects the loss of normal power, switches to a suitable backup supply, and works with the elevator control system to perform a programmed rescue sequence, depending on the elevator design. This means bringing the cabin to a suitable landing and opening the doors to allow passengers to deboard.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The order in which they occur depends on the elevator controller, drive system, backup power arrangement, and safety interlocks. An ARD is not a one-size-fits-all remedy, and the presence of an ARD does not relieve the need for proper maintenance, emergency communication, and trained rescue procedures.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">ARD systems can be used for residential, commercial, and other elevator installations where the equipment is compatible and the applicable requirements are met.<\/span><\/p>\n<h2><b>How Does an Elevator ARD Work?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">The working principle of an ARD involves several coordinated steps.<\/span><\/p>\n<h3><b>1. Detection of a Power Failure<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">In a normal case the elevator is driven by the building\u2019s electrical system. If that supply fails, the ARD or related control equipment detects the interruption.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The system should be able to distinguish the power failure from other conditions that might prevent normal elevator movement.<\/span><\/p>\n<h3><b>2. Switching to Backup Power<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">When the conditions are fulfilled, the system notices the interruption and employs its assigned backup power source, typically a battery arrangement.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The backup supply shall be compatible with the control equipment of the elevator and the rescue operation. It should not be assumed that each ARD will power the whole elevator under all conditions.<\/span><\/p>\n<h3><b>3. Evaluating the Elevator&#8217;s Condition<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The controller evaluates the system status and the conditions needed to perform the rescue sequence. Depending on the design, this may include information about cabin position, drive system, and safety circuits.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The system may not be able to execute the normal rescue sequence if a fault or safety condition prevents movement. Qualified personnel may then need to follow the manufacturer&#8217;s emergency procedure.<\/span><\/p>\n<h3><b>4. Moving the Cabin to a Suitable Landing<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Where the system supports automatic movement and the required conditions are met, the ARD coordinates with the elevator controls to move the cabin to a suitable floor.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The direction and movement strategy depend on the lift&#8217;s configuration and the manufacturer&#8217;s control logic. It is not correct to assume that every elevator always travels downward or always selects the nearest floor.<\/span><\/p>\n<h3><b>5. Enabling Passenger Exit<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">When the cabin is at the intended landing and the required safety conditions are met, the system allows the intended door-opening sequence.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The passengers can then leave the cabin in accordance with the operating procedure of the equipment. If the system does not complete the rescue operation, passengers should use the available alarm or communication facility and wait for authorised assistance rather than attempting to force the doors open.<\/span><\/p>\n<h2><b>Main Components of an Elevator ARD System<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An ARD operates through a combination of power, control, and safety components. The exact configuration varies by manufacturer and elevator type.<\/span><\/p>\n<h3><b>Backup Battery or Power Source<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The backup power source supplies the energy required for the supported rescue operation. Battery condition, charging arrangements, capacity, and compatibility affect system readiness.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">A degraded battery may prevent the intended rescue sequence from completing.<\/span><\/p>\n<h3><b>Power Monitoring and Switching Circuit<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The monitoring circuit detects the interruption of the normal supply. Associated switching arrangements transfer the supported equipment to the designated backup source when the operating conditions permit.<\/span><\/p>\n<h3><b>Elevator Controller<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The controller coordinates the elevator&#8217;s operation and communicates with the relevant control and drive equipment. During rescue operation, it follows the programmed sequence and monitors the necessary operating conditions.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For more information, read MAS Industries&#8217; article on the<\/span><a href=\"https:\/\/masind.net\/blog\/elevator-controller\/\"> <span style=\"font-weight: 400;\">elevator controller<\/span><\/a><span style=\"font-weight: 400;\">.<\/span><\/p>\n<h3><b>Drive and Motor Interface<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The drive and motor arrangement determine how the cabin can move during rescue operation. The ARD, controller, and drive must be compatible.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Some systems employ dedicated rescue hardware, while other systems incorporate rescue capability into compatible control and drive equipment.<\/span><\/p>\n<h3><b>Safety Circuits and Door Interlocks<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Safety circuits and door interlocks help ensure that elevator movement and door operation follow the designed safety sequence. Rescue functionality must work with these protections rather than bypassing them.<\/span><\/p>\n<h3><b>Status Indicators and Alarm Facilities<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Depending on the system, indicators may show operating status, faults, or battery conditions. Cabin alarms and communication systems provide additional ways for passengers to request help if necessary.<\/span><\/p>\n<h2><b>Key Benefits of an Elevator Automatic Rescue Device<\/b><\/h2>\n<h3><b>Helps reduce passenger entrapment during power interruptions<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">A compatible ARD can perform a defined rescue sequence without requiring an immediate manual intervention, when operating conditions allow.<\/span><\/p>\n<h3><b>Supports a more organised emergency response<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Automated rescue functionality can reduce uncertainty during certain power failures. It should be supported by clear emergency instructions and appropriate communication facilities.<\/span><\/p>\n<h3><b>Improves the overall safety provision<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">One part of the safety arrangements for an elevator is an ARD. It is as good as its interfacing with the controller, drive, backup power, door interlocks and other safety systems.<\/span><\/p>\n<h3><b>Supports residential and commercial elevator planning<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Power interruptions can affect elevators in homes, apartment buildings, offices, and commercial properties. Specifying an appropriate rescue arrangement helps building owners plan for these situations.<\/span><\/p>\n<h3><b>Helps facility managers plan maintenance<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Routine checks of backup power and rescue functionality can identify developing problems before the equipment is needed during an actual interruption.<\/span><\/p>\n<h2><b>How to Choose the Right ARD for a Lift<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">Selecting an ARD requires more than comparing product prices. It has to be compatible with the elevator where it would be installed.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Before making an acquisition, one should consider:<\/span><\/p>\n<ol>\n<li><b> Compatibility of the Elevator: <\/b><span style=\"font-weight: 400;\">Check the type of the elevator, type of the controller, the way of driving, and the rescue method.<\/span><\/li>\n<li><b> Compatibility of Power Supply\/Battery: <\/b><span style=\"font-weight: 400;\">The compatibility between the power supply\/battery and the rescue process has to be verified.<\/span><\/li>\n<li><b> Compatibility of the ARD with the elevator control panel\/drive:<\/b><span style=\"font-weight: 400;\"> The compatibility of the ARD with the elevator control panel\/drive in terms of communication and functionality needs to be verified.<\/span><\/li>\n<li><b> Rescue Process: <\/b><span style=\"font-weight: 400;\">The process by which the system will detect the power failure, determine the possibility of carrying out a rescue process, move the car, and open the doors should be explained by the supplier.<\/span><\/li>\n<li><b> Failure Indications: <\/b><span style=\"font-weight: 400;\">Check whether the equipment gives indications of problems in the battery, power, or system failure.<\/span><\/li>\n<li><b> Maintenance Requirements: <\/b><span style=\"font-weight: 400;\">Inquire about the replacement of batteries, inspection, availability of spare parts, and maintenance support.<\/span><\/li>\n<li><b> Relevant requirements: <\/b><span style=\"font-weight: 400;\">Consult the relevant Indian lift safety codes and manufacturer&#8217;s guidelines.<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\">To find compatible solutions, you can check out MAS Industries&#8217; <\/span><a href=\"https:\/\/masind.net\/products\/controller-drives\/\"><b>elevators&#8217; controller and drive systems<\/b><\/a><span style=\"font-weight: 400;\">, as well as the characteristics of the recommended equipment. Make sure that the ARD functionality is exactly what you need.<\/span><\/p>\n<h2><b>ARD Maintenance: What Should Be Checked?<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An ARD must be maintained so it is ready for the rescue operation it was designed to perform.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Important maintenance checks are :<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Looking at the backup battery and its installed charger.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Checking power connections and wiring.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Inspecting fault indications on the controller and drive.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Testing the rescue sequence using the manufacturer&#8217;s recommended method.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Supervised test to verify desired cabin motion and door operation.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Check the status of associated alarms and communications facilities.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Documenting inspection results and replacing worn or defective components when needed<\/span><\/li>\n<\/ul>\n<p><span style=\"font-weight: 400;\">Testing must be carried out by qualified elevator personnel in accordance with the manufacturer\u2019s procedure. Do not deliberately interrupt power or perform a rescue test without the proper controls and precautions.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The frequency of inspection shall be in accordance with the equipment manufacturer\u2019s instructions, applicable regulations, and the elevator maintenance plan.<\/span><\/p>\n<h2><b>ARD vs. Manual Elevator Rescue<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An ARD and a manual rescue procedure serve different purposes.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">An ARD is designed to perform a defined rescue sequence automatically when the necessary power, control, and safety conditions are satisfied. Manual rescue involves authorised personnel following the elevator manufacturer&#8217;s prescribed emergency procedure when automatic rescue is unavailable or unsuccessful.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Neither method should be treated as a reason to bypass safety interlocks or force elevator doors open. Building managers should ensure that emergency instructions and communication arrangements are available to occupants and that authorised service personnel understand the correct rescue procedure.<\/span><\/p>\n<h2><b>Common ARD Problems and Prevention<\/b><\/h2>\n<h3><b>Weak or deteriorated backup batteries<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Batteries lose capacity over time. Routine inspections and replacement according to the manufacturer&#8217;s recommendations help maintain readiness.<\/span><\/p>\n<h3><b>Incompatible control equipment<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">If the rescue device is not properly matched to the controller or drive, it may not work as intended. Before installing or replacing, check for compatibility.<\/span><\/p>\n<h3><b>Faulty wiring or power connections<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Loose connections or electrical faults can interfere with monitoring and switching. Qualified technicians should inspect and correct these issues.<\/span><\/p>\n<h3><b>Rescue operation not tested<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">The system may stay idle for extended periods, permitting faults to remain undetected. Scheduled testing helps to catch problems before they become a crisis.<\/span><\/p>\n<h3><b>Unclear emergency procedures<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Even a properly installed ARD cannot guarantee a successful rescue under every possible fault condition. Passengers and building staff should know how to raise an alarm and contact authorised assistance.<\/span><\/p>\n<h2><b>Conclusion<\/b><\/h2>\n<p><span style=\"font-weight: 400;\">An Elevator Automatic Rescue Device provides an important rescue function for compatible elevator systems during certain power interruptions. Its operation depends on the backup power source, controller, drive, safety circuits, and the conditions present when the interruption occurs.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">For building owners and lift buyers, the priority should be to select a compatible system, verify its operating sequence, and ensure that qualified technicians maintain and test it regularly.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">MAS Industries offers elevator electronic components and controller and drive products that may form part of a compatible elevator installation. Explore the <\/span><a href=\"https:\/\/masind.net\/\"><span style=\"font-weight: 400;\">MAS Industries<\/span><\/a><span style=\"font-weight: 400;\"> website and consult the relevant product team to confirm equipment specifications and compatibility for your project.<\/span><\/p>\n<h2><b>Frequently Asked Questions<\/b><\/h2>\n<h3><b>What is the full form of ARD in a lift?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">ARD stands for Automatic Rescue Device. It is designed to support a defined elevator rescue operation during certain power failures.<\/span><\/p>\n<h3><b>How does an ARD work during a power failure?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">A compatible system detects that the normal power is lost, uses its own backup supply, and, using the elevator controls, executes the programmed sequence of rescuing under the given conditions.<\/span><\/p>\n<h3><b>Does every elevator ARD work in the same way?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">No. Rescue direction, cabin movement, backup power requirements, and door operation depend on the elevator design, controller, drive, and manufacturer.<\/span><\/p>\n<h3><b>Can an ARD work if the elevator has a mechanical or electrical fault?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Not necessarily. A fault or safety condition may prevent movement or completion of the rescue sequence. Authorised personnel must follow the manufacturer&#8217;s emergency procedure.<\/span><\/p>\n<h3><b>How often should an ARD be maintained?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">Maintenance and testing shall be done according to the manufacturer\u2019s instructions, applicable regulations, and approved maintenance plan of the elevator. Qualified personnel should check the condition of the battery and rescue operation.<\/span><\/p>\n<h3><b>Is an ARD a replacement for elevator maintenance?<\/b><\/h3>\n<p><span style=\"font-weight: 400;\">No. An ARD is one element of the overall safety system. Routine elevator maintenance, functional testing, communication facilities, and appropriate emergency procedures remain essential.<\/span><\/p>\n<p><script type=\"application\/ld+json\">\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"BlogPosting\",\n  \"mainEntityOfPage\": {\n    \"@type\": \"WebPage\",\n    \"@id\": \"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/\"\n  },\n  \"headline\": \"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits\",\n  \"description\": \"When a power failure suddenly occurs, it can interrupt the operation of the elevator and can leave the passengers stuck and waiting inside the cabin. In such situations, an appropriately configured Automatic Rescue Device (ARD) can help move the elevator to a suitable landing so passengers can exit safely, provided the system is designed for that function and its operating conditions are met.\",\n  \"image\": \"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/10\/image2-1.png\",  \n  \"author\": {\n    \"@type\": \"Organization\",\n    \"name\": \"\"\n  },  \n  \"publisher\": {\n    \"@type\": \"Organization\",\n    \"name\": \"\",\n    \"logo\": {\n      \"@type\": \"ImageObject\",\n      \"url\": \"\"\n    }\n  },\n  \"datePublished\": \"2026-10-28\"\n}\n<\/script><\/p>\n","protected":false},"excerpt":{"rendered":"<p>When a power failure suddenly occurs, it can interrupt the operation of the elevator and can leave the passengers stuck and waiting inside the cabin. In such situations, an appropriately configured Automatic Rescue Device (ARD)&#8230;<\/p>\n","protected":false},"author":1,"featured_media":1340,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-1342","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v24.9 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits - MAS blog<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits - MAS blog\" \/>\n<meta property=\"og:description\" content=\"When a power failure suddenly occurs, it can interrupt the operation of the elevator and can leave the passengers stuck and waiting inside the cabin. In such situations, an appropriately configured Automatic Rescue Device (ARD)...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/\" \/>\n<meta property=\"og:site_name\" content=\"MAS blog\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-28T14:08:48+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-10T13:01:18+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/10\/image2-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"9 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/\",\"url\":\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/\",\"name\":\"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits - MAS blog\",\"isPartOf\":{\"@id\":\"https:\/\/masind.net\/blog\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#primaryimage\"},\"image\":{\"@id\":\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#primaryimage\"},\"thumbnailUrl\":\"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/10\/image2-1.png\",\"datePublished\":\"2026-10-28T14:08:48+00:00\",\"dateModified\":\"2026-11-10T13:01:18+00:00\",\"author\":{\"@id\":\"https:\/\/masind.net\/blog\/#\/schema\/person\/17d631215febbdc029be2d12116fbcf2\"},\"breadcrumb\":{\"@id\":\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#primaryimage\",\"url\":\"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/10\/image2-1.png\",\"contentUrl\":\"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/10\/image2-1.png\",\"width\":1536,\"height\":1024,\"caption\":\"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/masind.net\/blog\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/masind.net\/blog\/#website\",\"url\":\"https:\/\/masind.net\/blog\/\",\"name\":\"MAS blog\",\"description\":\"Just another WordPress site\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/masind.net\/blog\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\/\/masind.net\/blog\/#\/schema\/person\/17d631215febbdc029be2d12116fbcf2\",\"name\":\"admin\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/masind.net\/blog\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/d7375bd2ffc3d4c2030fb3812811d26388a1486dbcb3414bf3123f1961507ba6?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/d7375bd2ffc3d4c2030fb3812811d26388a1486dbcb3414bf3123f1961507ba6?s=96&d=mm&r=g\",\"caption\":\"admin\"},\"sameAs\":[\"http:\/\/localhost:8888\/idigitaliseblog\"],\"url\":\"https:\/\/masind.net\/blog\/author\/admin\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits - MAS blog","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/","og_locale":"en_US","og_type":"article","og_title":"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits - MAS blog","og_description":"When a power failure suddenly occurs, it can interrupt the operation of the elevator and can leave the passengers stuck and waiting inside the cabin. In such situations, an appropriately configured Automatic Rescue Device (ARD)...","og_url":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/","og_site_name":"MAS blog","article_published_time":"2026-10-28T14:08:48+00:00","article_modified_time":"2026-11-10T13:01:18+00:00","og_image":[{"width":1536,"height":1024,"url":"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/10\/image2-1.png","type":"image\/png"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"9 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/","url":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/","name":"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits - MAS blog","isPartOf":{"@id":"https:\/\/masind.net\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#primaryimage"},"image":{"@id":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#primaryimage"},"thumbnailUrl":"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/10\/image2-1.png","datePublished":"2026-10-28T14:08:48+00:00","dateModified":"2026-11-10T13:01:18+00:00","author":{"@id":"https:\/\/masind.net\/blog\/#\/schema\/person\/17d631215febbdc029be2d12116fbcf2"},"breadcrumb":{"@id":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#primaryimage","url":"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/10\/image2-1.png","contentUrl":"https:\/\/masind.net\/blog\/wp-content\/uploads\/2026\/10\/image2-1.png","width":1536,"height":1024,"caption":"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits"},{"@type":"BreadcrumbList","@id":"https:\/\/masind.net\/blog\/elevator-automatic-rescue-device-ard-working-principle-components-and-safety-benefits\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/masind.net\/blog\/"},{"@type":"ListItem","position":2,"name":"Elevator Automatic Rescue Device (ARD): Working Principle, Components and Safety Benefits"}]},{"@type":"WebSite","@id":"https:\/\/masind.net\/blog\/#website","url":"https:\/\/masind.net\/blog\/","name":"MAS blog","description":"Just another WordPress site","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/masind.net\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/masind.net\/blog\/#\/schema\/person\/17d631215febbdc029be2d12116fbcf2","name":"admin","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/masind.net\/blog\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/d7375bd2ffc3d4c2030fb3812811d26388a1486dbcb3414bf3123f1961507ba6?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/d7375bd2ffc3d4c2030fb3812811d26388a1486dbcb3414bf3123f1961507ba6?s=96&d=mm&r=g","caption":"admin"},"sameAs":["http:\/\/localhost:8888\/idigitaliseblog"],"url":"https:\/\/masind.net\/blog\/author\/admin\/"}]}},"_links":{"self":[{"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/posts\/1342","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/comments?post=1342"}],"version-history":[{"count":2,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/posts\/1342\/revisions"}],"predecessor-version":[{"id":1345,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/posts\/1342\/revisions\/1345"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/media\/1340"}],"wp:attachment":[{"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/media?parent=1342"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/categories?post=1342"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/masind.net\/blog\/wp-json\/wp\/v2\/tags?post=1342"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}